The Synchronizer coordinates the timing between your PIV hardware:
- High speed multi purpose timing unit
- 16 trigger outputs (TTL compatible)
- 8 trigger inputs (TTL compatible)
- 8 channels logic analyzer
- freely configurable routing of all channels
- Pulse to Pulse resolution: 20ps
- Maximum repetition rate: 7.4 MHz
- Sequence duration up to several weeks
- Compact casing
- Incremental encoder mode
- Ethernet connectivity
- Ultra low Jitter (< 1ps)
- Rise/Fall time <2ns
- High power TTL outputs
- Pulse voltage adjustable on request
- Signals individually switchable (on / off / invert)
- Free configurable trigger logic (AND / OR / XOR / NOT)
- Free configurable trigger window and trigger delay
- Ultra quick response of external triggers
- Status LEDs for each signal